CDR 300 - 4
Back To List- Input : 3 x 380 V / 50 Hz 125 KVA
- Output : 3 x 380 V / 50 Hz 125 KVA
- Circuits per cabinet : Up to 4
- Parallel work : Yes
Main features
- Power supply: 3 х 380V / 50 (or 60) Hz;
- Power consumption - up to 125 KVA;
- Number of independent circuits - 4. All circuits are galvanically isolated!;
- Output current in charge and discharge mode for a circuit : 0 - 75 A;
- Output voltage - from 15 to 360 V;
-
Work modes
- Charge;
- Discharge;
- CV (Constant Voltage);
- CC (Constant Current);
- CP (Constant Power). ;
- Мean square error of the output current : <= 0.5% + 0.2А;
- Мicroprocessor control;
- Interface for connection to a centralized management system - RS 485. Ability to connect to formation modules (with acid recirculation) of O.M.I Italy via PROFIBUS;
- Ability to work in parallel mode to increase output current;
- Four galvanically isolated channels for temperature measurement (one per circuit);
- Recording of accumulated amper-hours, watt-hours, output power, current, voltage, etc.;
- Cooling - forced, bottom-up;
-
Safety
- turning off power of power block when circuit is not working;
- fuses at the output of each circuit;
- automatic fuses at the input of each power block;
- duplication of hardware protection with electronic and software;
- electroless commutation of input contactors for each circuit. ;
- Cabinet dimensions (W x D x H) [mm] : 750 x 800 x 1920;
- Weight : ~ 900 kg;
Software features
- Creation and editing of multi-step formation programs,
- Grouping circuits for parallel work,
- Uploading, starting, stopping and interrupting of formation programs,
- Visualization of rectifier’s current state on main window,
- Storing sample measurement data for all tests in a database,
- Visualization of stored data from database, drawing charts etc.,
- Printing report data,
- Export process data in Excel file format.