BTS 600 A / 18 V

Back To List

  • Input : 3 x 380 V / 50 Hz 19KVA
  • Output : 6 x 100 A / 18 V / 1800 W
  • Circuits per cabinet : Up to 6
  • Parallel work : Yes

Main features

  • Power supply: 3 х 380V / 50Hz / 19 KVA;
  • Number of independent circuits (single battery per circuit) - 6. All circuits are galvanically isolated!;
  • Ability to work in parallel mode;
  • Max.output current in charge and discharge mode for single channel - 100 A;
  • Max. output current in parallel mode : up to 600 A (depending on channels working in parallel);
  • Max.output voltage : 18 V;
  • Work modes: Charge, Discharge, CV, CC, CP;
  • PLC for each channel, which provides
    • Temporary storage of test data in case of a lost connection to a PC and immediately sending it to the PC when connection is restored ;
    • Visualization of main test parameters-current, voltage, amperhours etc.;
    • Auto restart test after restoring of broken power supply;
    • Data acquisition rate – 100 ms.;

Software features

  • Creation and editing of multi-step test programs,
  • Creation and editing of multi-step test programs,
  • Storing sample measurement data for all tests in a database,
  • Visualization of stored data from database, drawing charts etc.,
  • Printing report data,
  • Export test data in Excel file format.