CDT-2CH 3(4.4)/100

Back To List

  • Input : 3 х 380V / 50Hz / 6 000 VA
  • Output : 8 x 100 A / 3 V
  • Circuits per cabinet : Up to 8
  • Parallel work : Yes

Main features

  • Power supply: 3 х 380V / 50Hz / 6 000 VA;
  • Number of charge/discharge channels (single cell per channel) in cabinet : 8. All circuits are galvanically isolated!;
  • Ability to work in parallel mode;
  • Max. output current in charge and discharge mode for single channel : 100 A;
  • Max. output current in parallel mode : up to 800 A (depending on channels working in parallel);
  • Max.output voltage : 3V (4.4V - in another model) ;
  • Min. voltage in discharge mode : 0.9 V;
  • Accuracy of current : ± 0.2% FSR, Resolution: 0.01 A;
  • Accuracy of voltage : ± 0.1% Full Scale. Resolution: 0.001V;
  • ADC : 15 bit;
  • Galvanically isolated cell voltage measurement for each channel;
  • Galvanically isolated potentials measurement with reference electrode for each channel ;
  • Galvanically isolated temperature measurement for each channel;
  • Work modes: Charge, Discharge, CV, CC, CP
  • PLC for each channel, which provides
    • Temporary storage of test data in case of a lost connection to a PC and immediately sending it to the PC when connection is restored ;
    • Visualization of main test parameters-current, voltage, amperhours etc.;
    • Auto restart test after restoring of broken power supply;
    • Data acquisition rate – 100 ms.;
  • Electronic commutation when switching charge and discharge modes;
  • Mechanical construction
    • Modular (2 channels in a module);
    • Each module can operate independently, outside the cabinet, powered with 220 V power supply;
    • Cabinet dimensions (H X W x D) [mm] ;

Software features

  • Creation and editing of multi-step test programs,
  • Grouping circuits for parallel work,
  • Uploading, starting, stopping and interrupting of test programs,
  • Visualization of tester’s current state on main window,
  • Storing sample measurement data for all tests in a database
  • Visualization of stored data from database, drawing charts etc.,
  • Printing report data,
  • Export test data in Excel file format.