DT2000A/12V – 4CH
Back To List- Input : 220V / 50Hz / 1 500 VA
- Output : 4 x 500 A (2000 A parallel) / 220 V
- Circuits per cabinet : Up to 4
- Parallel work : Yes
Main features
- Power supply: 220V / 50Hz / 1 500 VA;
- Number of discharge channels: 4. All circuits are galvanically isolated!;
- Ability to work in parallel mode : 4 x 500 A = 2000 A;
- Max. output current in discharge mode for each channel: 500 A;
- Max. output current in parallel mode : up to 2000 A (depending on channels working in parallel);
- Max. battery voltage : 13,5 V;
- Min. voltage in discharge mode : 3 V;
- Accuracy of current : ± 0.2% FSR, Resolution: 0.1 A;
- Accuracy of voltage : ± 0.1% Full Scale. Resolution: 0.001V;
- ADC : 15 bit;
- Galvanically isolated battery voltage measurement for each channel;
- Galvanically isolated temperature measurement for each channel;
- Work modes: Discharge CC, CP;
-
PLC for each channel, which provides
- Temporary storage of test data in case of a lost connection to a PC and immediately sending it to the PC when connection is restored ;
- Visualization of main test parameters-current, voltage, amp-hours etc.;
- Auto restart test after restoring of broken power supply;
- Data acquisition rate – 100 ms.;
- Dimensions (H X W x D) [mm] : not more than 2000 x 750 x 800;
Software features
- Creation and editing of test programs,
- Grouping circuits for parallel work,
- Uploading, starting, stopping and interrupting of test programs,
- Visualization of tester’s current state on main window,
- Storing sample measurement data for all tests in a database,
- Visualization of stored data from database, drawing charts etc.,
- Printing report data,
- Export to Excel;